Week 3

Sand to Power · workbook

Week 3: Photovoltaics: series, parallel and real systems

Name:Date:

Lessons

  1. Volts, amps and watts, The three words you need for every solar conversation.
  2. Series and parallel, Two ways to connect panels, and what each one changes.
  3. Shade, heat and cold mornings, Why one leaf matters and why the coldest day sets the limit.
  4. Real systems: grid-tie, off-grid, hybrid, Three kinds of system and the parts each one needs.
  5. Simulation: the Wiring Bench, Wire real panels, shade them and protect the charger.
  6. Put it to work, Plan a safe system for your own home.
  7. Week 3 checkpoint, Three questions to lock in the week.

Key words

Volt (V)
The ‘push’ of electricity.
Amp (A)
The amount of electricity flowing.
Watt (W)
Power: volts × amps. How fast energy is made or used.
kWh (kilowatt-hour)
A unit of energy: 1,000 watts used for one hour. Electricity bills are counted in kWh.
Voc (open-circuit voltage)
A panel's voltage when nothing is connected. It's the highest voltage it makes, higher when cold.
Isc (short-circuit current)
A panel's current when its + and − are joined directly. The most current it can give.
Maximum power point (MPP)
The one combination of volts and amps where a panel gives the most power.
Temperature coefficient
How much a panel's voltage or power changes per °C. Panels lose power when hot and gain voltage when cold.
DC (direct current)
Electricity flowing one way. Panels and batteries make DC.
AC (alternating current)
Electricity that switches direction many times a second. Wall sockets and the grid use AC.
Inverter
A device that changes panels' or batteries' DC into AC for home appliances or the grid.
kWp (kilowatt-peak)
The size of a solar system: its power in standard full sun. 10 panels of 410 W = 4.1 kWp.
Series
Connecting things end-to-end (+ to −). Voltages add, current stays the same.
String
A group of panels wired in series.
Parallel
Connecting all + together and all − together. Currents add, voltage stays the same.
Wire size (gauge / mm²)
How thick a wire is. More current needs thicker wire or it overheats.
Fuse / breaker
A safety part that cuts the circuit if too much current flows.
I–V curve
A graph of a panel's current against its voltage. Its shape shows shade and faults.
MPPT (maximum power point tracker)
Electronics inside chargers and inverters that keep panels at their maximum power point.
Charge controller
A device between panels and a battery that charges safely and stops at full.
Hot spot
A shaded or broken cell forced to carry current backwards; it heats up and can burn the panel.
Bypass diode
A one-way electrical valve in the junction box that lets current go around a shaded part of a panel.
Grid-tie
A system that sends solar power into the utility grid, usually with no battery.
Off-grid
A system not connected to the utility grid; it needs batteries for night.
Grounding / earthing
Connecting metal frames to the earth so a fault can't make them live.
Permit / interconnection
Official approval to install a system or connect it to the grid.

Worked examples

Volts, amps and watts

How much energy in a day?

A 4.1 kWp system gets 5 peak sun hours on a good day and loses about 14% to heat, wiring and the inverter. How many kWh?

  1. 4.1 kW × 5 h = 20.5 kWh.
  2. 20.5 × (1 − 0.14) ≈ 17.6 kWh.

Answer: About 17.6 kWh, enough for a fridge, lights, fans and a TV for a day, with some to spare.

Now try your own numbers:

Series and parallel

Two strings of two

You wire 2 panels in series, then put 2 of those strings in parallel. Each panel is 37.5 V and 13.9 A.

  1. Series: 2 × 37.5 = 75 V.
  2. Parallel: 2 × 13.9 = 27.8 A.
  3. Power: 75 × 27.8 ≈ 2.1 kW.

Answer: 75 V at 27.8 A, about 2.1 kW. Try other layouts below.

Now try your own numbers:

Shade, heat and cold mornings

How many in series?

Your charge controller allows 250 V. The panel's Voc is 37.5 V. Your coldest morning is −12 °C.

  1. Rise: 0.26% × (25 − (−12)) = 0.26% × 37 ≈ 9.6%.
  2. Cold Voc per panel: 37.5 × 1.096 ≈ 41.1 V.
  3. 250 ÷ 41.1 ≈ 6.08 → 6 panels maximum.

Answer: Six panels at most. In Chicago (−27 °C) it drops to five. Try your city below.

Now try your own numbers:

My action plan

Ideas from “Put it to work”: Start safe with a 12 V portable kit (panel, charge controller, small LFP battery) for lights and phones. · For a home system, list your loads, then use Lesson 3.3's calculator to check strings against the inverter you're quoted. · Ask your installer for the string-sizing sheet and coldest-temperature used.

One thing I learned that surprised me

One step I'll take in the next 30 days

Who I'll talk to (installer, electrician, partner, lender)

What I still need to find out

For learning only. Check local codes and use qualified professionals for electrical and battery work.